Waterflood Filtration Unit

WATERFLOOD FILTRATION UNIT

PETREX Job No. J0041

Delivered:  January 1996

Location:  Offshore India 

This unit is designed to filter 90,000 BPD of seawater utilizing two stages of filtration.  First stage consist of self-cleaning wire screen coarse strainers.  Second stage consists of pressurized down-flow garnet media filters.  PLC controller activates automatic backwash sequence with one filter offline and two in service.

 Major Equipment:   

  Media Filters:  84” O.D. x 5’-6” S/S, ASME Code  
  Self cleaning Strainers: 10” ANSI 150 x 26” O.D.  
     
Size: 37’ x 15’ x 12’    

 