Hydrogen Unit

PROPRIETARY HYDROGEN EXTRACTION UNIT

PETREX Job No. J0037

Delivered: December 1995

Location: Major Louisiana Oil Refinery

This proprietary unit is designed to recover hydrogen from a refinery gas stream of 8.5 MMSCFD at a pressure of 2675 PSIG. The patented process technology utilizes a proprietary membrane separator which the gas stream enters after being scrubbed by a filter-separator upstream. Electric trace heating and PLC control panel are incorporated into the unit.

Major Equipment:

  H.P. Filter-Separator:  8" O.D. x 10’-0" S/S, ASME Code
  H.P. Membrane Permeator: 16" O.D. x 12’-0" S/S, ASME Code
     
Size:  10’ x 11’ x 16’  

   