Hydrogen Unit

PROPRIETARY HYDROGEN EXTRACTION UNIT
PETREX Job No. J0037
Delivered: December 1995
Location: Major Louisiana Oil Refinery
This proprietary unit is designed to recover hydrogen from a refinery gas stream of 8.5 MMSCFD at a pressure of 2675 PSIG. The patented process technology utilizes a proprietary membrane separator which the gas stream enters after being scrubbed by a filter-separator upstream. Electric trace heating and PLC control panel are incorporated into the unit.
Major Equipment:
| H.P. Filter-Separator: | 8" O.D. x 10’-0" S/S, ASME Code | |
| H.P. Membrane Permeator: | 16" O.D. x 12’-0" S/S, ASME Code | |
| Size: | 10’ x 11’ x 16’ |