Flex-Tube™ Application Data |
|
SPECIFICATIONS |
Rev. 6/98 |
|
MODEL |
TANK DIAMETER |
WORKING PRESSURE |
TANK MATERIAL |
INLET OUTLET |
DRAIN |
|
EC 140 EC 145 EC 225S EC 350S EC 500S EC 700S EC 1275 EC 1675 EC 2100 |
16 in. 18 in. 24 in. 30 in. 36 in. 42 in. 48 in. 60 in. 60 in. |
50 psi. 50 psi. 50 psi. 50 psi. 50 psi. 50 psi. 50 psi. 50 psi. 50 psi. |
304L 304L 304L 304L 304L 304L 304L 304L 304L |
2 1/2-8 NPT 2 1/2-8 NPT 4 x 9 6 x 11 6 x 11 8 x 13 1/2 8 x 13 1/2 10 x 16 10 x 16 |
2 1/2-8 NPT 2 1/2-8 NPT 3 x 7 1/2 NPT 4 x 9 4 x 9 4 x 9 4 x 9 4 x 9 4 x 9 |
Standard tank construction is non-code, safety factor =4
OPERATION DATA
|
MODEL |
GPM RANGE |
PRECOAT LBS. |
HEADLOSS CLEAN |
HEAD- LOSS* |
BUMP SYSTEM |
OPER. WEIGHT |
|
EC 140 EC 145 EC 225S EC 350S EC 500S EC 700S EC 1275 EC 1675 EC 2100 |
75-122 105-171 212-335 337-565 528-835 719-1138 950-1505 125-1670 1560-2490 |
17 24 50 79 117 158 210 272 350 |
1.5 ft. 1.5 ft. 1.5 ft. 1.5 ft. 1.5 ft. 1.5 ft. 1.5 ft. 1.5 ft. 1.5 ft. |
50 ft. 50 ft. 50 ft. 50 ft. 50 ft. 50 ft. 50 ft. 50 ft. 50 ft. |
Man-Air Man-Air Elec-Air Elec-Air Elec-Air Elec-Air Elec-Air Elec-Air Elec-Air |
625 800 1500 3200 4250 5700 7700 12,000 13,800 |
* Solids laden filter before regeneration
PERFORMANCE
|
MODEL |
OPTIMUM GPM |
TURNOVER - U. S. GALLONS |
||
|
4 Hrs |
6 Hrs |
8 Hrs |
||
|
EC 140 EC 145 EC 225S EC 350S EC 500S EC 700S EC 1275 EC 1675 EC 2100 |
100 140 285 475 703 958 1,268 1,650 2,085 |
24,000 33,600 68,400 114,000 168,720 229,920 304,320 396,000 500,400 |
36,000 50,400 102,600 171,000 253,080 344,880 456,480 594,000 750,600 |
48,000 67,200 136,800 228,000 337,440 459,840 608,640 792,000 1,000,800 |
| Home | Site Map | About | Contact Us |
Copyright© 2006